Hazardous area Ammonia detector X5

  • Simultaneous detection of two different gases
  • IONIC sensor with a lifespan of 5+ years
  • Two analog outputs (4–20 mA)
  • Three dry contact relay outputs
  • Color digital display for real-time gas concentration, alarms, and fault indication
  • Easy service and maintenance
  • Explosion-proof, IECEx / ATEX certified for Zone 1 & 2, Zone 21 & 22
  • Manufactured in the UK (Made in UK)

Description

Designed for industrial ammonia (NH₃) detection to ensure worker safety

Suitable for installation in production facilities, storage tanks, refrigeration systems, laboratories, and more.

The detector is equipped with an Ionic Ammonia sensor with a lifespan of over 5 years.
The sensor is resistant to humidity and can operate in low temperatures down to -40°C.


Detection Ranges (Ammonia):

  • 0–100 ppm (TOC-102-NH3-1)
  • 0–500 ppm (TOC-102-NH3-5)
  • 0–5,000 ppm (TOC-102-NH3-50)

Dual Gas Detection Capability

This detector can measure two different gases simultaneously, thanks to its dual-sensor design:

  • One sensor dedicated to ammonia
  • Second sensor configurable for an additional gas of your choice

The detector features two independent channels, meaning each sensor operates separately—essentially providing two detectors in one unit.

Each channel includes a separate 4–20 mA analog output, allowing easy integration with external systems (e.g., fire detection systems or control systems).


Display & Status Indication

  • Real-time gas concentration displayed on a color digital screen
  • Green – Normal operation
  • Red – Alarm condition
  • Orange – Fault

Installation & Safety

  • ATEX certified, suitable for hazardous areas (Zone 1 & Zone 2)
  • Explosion-proof design
  • Remote sensor capability via cable

Example:
For gases with different densities (e.g., hydrogen – lighter than air, LPG – heavier than air), one sensor can be mounted on the detector and the second remotely for optimal detection.


Optional Second Sensor – Supported Gases

  • Carbon Monoxide (CO)
  • NOx compounds
  • Chlorine (Cl₂)
  • Sulfur Dioxide (SO₂)
  • Oxygen deficiency (O₂)
  • Hydrogen Sulfide (H₂S)
  • Flammable gases (LEL %) such as methane, hydrogen, propane, LPG, methanol, and more
  • Volatile Organic Compounds (VOC)
  • Refrigerant gases

PID Sensors (IGD – 30,000-hour lamp life)

  • 0–50 ppm (TOC-102-PID05)
  • 0–100 ppm (TOC-102-PID01)
  • 0–200 ppm (TOC-102-PID02)
  • 0–2,000 ppm (TOC-102-PID20)
  • 0–5,000 ppm (TOC-102-PID50)

Refrigerant Sensors

  • Infrared (IR) 0–2,000 ppm (TOC-102-IRR)
  • R1 Group 0–1,000 ppm (TOC-102-R1)
  • R2 Group 1,000–10,000 ppm (TOC-102-R2)

Flammable Gas Detection

  • Hydrogen 0–1,000 ppm (TOC-102-H2)
  • Infrared (IR) 0–100% LEL (TOC-102-IRF)
  • Methane IR 0–100% VOL (TOC-102-HIRF)
  • MK8 Pellistor 0–100% LEL (TOC-102-MK8)
  • Acetylene 0–200 ppm (TOC-102-C2H2)

Oxygen Sensor (Long Life, Lead-Free)

  • 0–25% VOL (TOC-102-O2)

Toxic & Specialty Gases

  • Boron Trichloride 0–10 ppm
  • Carbon Monoxide 0–100 ppm / 0–2,000 ppm
  • Carbon Dioxide 0–5,000 ppm / 0–5% / 0–100% VOL
  • Hydrogen Sulfide 0–50 ppm / 0–5,000 ppm
  • Hydrogen Chloride 0–10 ppm
  • Nitric Oxide 0–100 ppm
  • Nitrogen Dioxide 0–20 ppm
  • Silane 0–10 ppm
  • Sulfur Dioxide 0–5 ppm
  • Formaldehyde 0–5 ppm
  • Carbon Disulfide 0–100 ppm
  • Ethylene Oxide 0–10 ppm / 0–100 ppm
  • Sulfur Hexafluoride (SF₆) 0–1,000 ppm

Technical Specifications

  • Power Supply: 18–32 VDC
  • Operating Temperature: -40°C to +55°C
  • Sensor Protection: Stainless Steel 316
  • Enclosure: Aluminum (copper-free) JB housing, optional Stainless Steel 316
  • Cable Entries: 2 × M20 (optional NPT)
  • Weight: 1.5 kg
  • Dimensions: Ø110 mm × 130 mm height
  • Protection Rating: IP66 (dust & water resistant)
  • Explosion-proof design